Zoek
Sluit dit zoekvak.

Terra Food-Tech CFS-V series

Raypa

Terra Food-Tech CFS-V series

Compact autoclaves for canned food.

From 33 to 175 litres

Informatie

Retorts with counter pressure

Both pasteurization and sterilization are techniques of food preservation by applying heat. Their aim is the destruction of microorganisms and their spores. The difference between the two techniques lies in the time and temperature of the heating process.

Sterilization

Sterilization is performed with different foods, such as meat, fish, vegetables, fruit…  it consists in placing food in a container and subjecting it to temperatures above 100ºC, usually 121ºC, during a certain period of time. After this process, all microorganisms and spores are inactivated.

Pasteurisatie

Pasteurization involves heating food at temperatures below 100ºC for a brief period of time. This method is used in many products, especially in milk and its derivatives, flavored juices, beers, because the low temperatures respect and preserve the aromas and other organoleptic characteristics. These food products have a shorter shelf life, because although viable microorganisms are drastically reduced, some remain viable.

FEATURES

Vertical sterilizers CFS-28V CFS-50V CFS-75V CFS-110V CFS-150V
Camera dimensions Ø x H cm 30 x 40 30 x 70 40 x 60 40 x 85 50 x 75
Camera volume – total/útil L 33 / 28 55 / 50 79 / 75 115 / 110 175 / 150
External dimensions F x A x H cm 56 x 51 x 112 56 x 51 x 130 73 x 62 x 119 73 x 63 x 144 85 x 76 x 140
Weight Kg 90 110 140 180 265
Electric power W 3200 3200 6000 6000 9000
Electrical voltage V* 230 (1P+N) 230 (1P+N) 400 (3P+N) 400 (3P+N) 400 (3P+N)
Frequency Hz 50/60 50/60 50/60 50/60 50/60
Packaging dimensions F x A x H cm 71 x 65 x 117 72 x 65 x 153 77 x 83 x 137 77 x 83 x 159 94 x 90 x 156
Weight with the packaging Kg** 95 115 150 205 285

 

Online calculator

Sometimes it’s difficult to know which model you should choose. That is why Raypa TERRA Food-Tech has developed an online calculator. The only thing you need to know it the dimensions of your containers. The tool will calculate the maximum number of containers per cycle you can sterilize with the different autoclaves.

Safety measures

  • Safety Valve
  • Safety Thermostat
  • Open door alarm
  • System door lock with positive pressure detector
  • Detector of water pressure
  • Water level Detector
  • Heat shield around the door
  • Protecting chassis for the sterilization chamber

Regulations

European rules regulations and directives in compliance are:

UNE-EN-ISO 9001:2015 Quality management system
A-61010-1 Safety requirements for electrical equipment for measurement, control and laboratory use. Part 1: General Requirements
A 2-040-61010-2-040 Part: Particular requirements for laboratory autoclaves
A-61326 Electrical equipment for measurement, control and laboratory use. Requirements of electromagnetic compatibility (EMC)
AD 2000 Merkblatt Pressure Vessels
2014/35/EU Low Voltage Directive
2014/30/EU Electromagnetic Compatibility
2014/68/EU Pressure Equipment