World Wildlife Fund (WWF) & RBC Tech for Nature and Microsoft have named MANTECH’s PeCOD® as a finalist for the Nature x Carbon Challenge! This challenge is to support community accessible carbon analysis technology for nature-based climate solutions(NbCS) to combat biodiversity loss and climate change.
Mantech MT Series of Automated Environmental Titration and Multi-Parameter Analyzers
Whether your laboratory requires a simple pH system or a system with eight parameters, MANTECH will deliver. We realize each laboratory is unique and as a result, our systems are tailor configured with off-the-shelf modules to meet your requirements for sample volume, parameters and sample size. Each system is fully automated by easy to use software and robust robotics.
Parameters: Acidity, alkalinity, ammonia, chloride, color, conductivity, fluoride, nitrate, oxidation-reduction potential (ORP), oxygen, pH, salinity, temperature, total hardness, turbidity
Mantech PeCOD: Fast and Portable COD (Chemical Oxygen Demand) Analyzer
MANTECH’s revolutionary PeCOD® COD Analyzer technology provides accurate chemical oxygen demand (COD) results in 10 minutes — without the use of harmful chemicals including dichromate and mercury.
Highly adaptable for wastewater and drinking water applications, the PeCOD® COD Analyzer’s patented nanotechnology-based approach to COD analysis will save you time and money while protecting the environment and the health and safety of your workers.
CEM Mars 6: microwave digestion for heavy metal analysis
For over 30 years chemists have trusted CEM to provide the highest quality microwave digestion systems for their laboratories. The MARS is simply the easiest to use, safest and most intelligent system on the market. It is the only system that uses integrated sensor technology to recognize the vessel type as well as the sample number then apply the appropriate amount of power to ensure the highest quality digest. With options for remote system control and contactless all vessel temperature control, the MARS is ready to handle your most difficult samples.
CEM Edge: automated extraction
The EDGE® is an automated extraction system that’s faster than Soxhlet, more automated than QuEChERS, and simpler than other solvent extraction systems. Extract a wide range of samples and sizes at least 3 times faster than other pressurized fluid extractors. This includes filtering, cooling, and washing. The EDGE has revolutionized the extraction process for sample preparation.
For example: Fat, Pesticides, Dioxins, PAH, PFAS, etc.
CEM SAM255: Parallel fast sample drying microwave
The SAM 255™ is a unique instrument for rapidly drying samples up to 1kg in size. It can be used for moisture analysis or as a preparatory step for further analysis. Drying times are reduced from hours to minutes with the precision of a conventional oven method. Almost any material can be dried using microwave energy as the volatile component can be water or a wide range of polar organic compounds. The system also features a unique design avoiding problems with reflected power that prevents complete drying of samples in conventional microwave ovens.
Elementar TOC analyzers
The concentration of total organic carbon (TOC) in liquid and solid samples is one of the most important screening parameters in water and environmental analysis. Whether you look at the evaluation of water quality, waste disposal or cleaning validation – the evaluation of organic pollution is always needed. For TOC and water analysis Elementar offers fast and easy determination of total organic carbon in liquids and solids. In addition, further elements and parameters can be determined with our flexible TOC analyzers.
These instruments use either high-temperature combustion or chemical oxidation combined with UV radiation. This enables us to offer the best suitable technique for your applicational needs. No matter if you want to determine TOC in ultra-pure water, drinking water, surface water, sea water, concentrated hydrochloric acid, waste water, soil eluates, soils, sediments or solid waste – we always have the perfect solution for your application.
Elementar Rapid N exceed & Rapid MAX N exceed: Nitrogen analyzer
Nitrogen plays an important role in the production process of nitrogen fertilizers and in the assessment of soil fertility. Elementar is the pioneer of the Dumas combustion analysis for the determination of Nitrogen from macro samples into the gram range, which currently replaces more and more the wet-chemical Kjeldahl method.
The dedicated nitrogen and protein analyzers use the high-temperature combustion method according to Dumas, ensuring a cost-effective and eco-friendly nitrogen and protein determination in your solid or liquid sample. In combination with our innovative EAS REGAINER® Technology incorporated into our nitrogen and protein analyzers, protein analysis becomes even more cost-effective compared to conventional Dumas combustion analyzers. A major expense of traditional Dumas combustion is the reduction metals needed to bind excess oxygen and convert nitrogen oxides to molecular nitrogen. With our patent-pending EAS REGAINER® Technology, this cost has been greatly reduced, further driving the advantage of these Dumas analyzers over comparable systems. Combined with their reliable and robust design, our analyzers offer unsurpassed high laboratory efficiency in nitrogen and protein analysis.